TONNY INSTRUMENT TECHNOLOGY CO., LTD. Laboratory testing instruments since 2012

ISO 22609 FAQ: instruments, ranges and method scope

ISO 22609 FAQ: instruments, ranges and method scope - laboratory illustration

The TNG1044 and TNG1049 instruments are designed to meet the requirements of ISO 22609 for synthetic blood penetration testing of face masks.

How does the TNG1044 support ISO 22609 testing?

ISO 22609 FAQ: instruments, ranges and method scope - laboratory test illustration

The TNG1044 Face Mask Synthetic Blood Penetration Tester is specifically designed to comply with ISO 22609. It features a blood spraying distance of (300 ± 10) mm, which aligns with the standard's requirement for simulating real-world conditions. Additionally, the nozzle inner diameter of 0.84 mm ensures consistent and accurate application of synthetic blood during testing.

What specifications ensure accurate synthetic blood application on the TNG1044?

The TNG1044 includes a nozzle length of 12.7 mm, which helps maintain the correct distance between the nozzle and the test sample, ensuring uniform spray distribution. The spraying speed options of 450 cm/s, 550 cm/s, and 635 cm/s allow for precise control over the test conditions, supporting the standard's requirement for consistent and repeatable results.

How does the TNG1049 complement the TNG1044 in testing?

ISO 22609 FAQ: instruments, ranges and method scope - laboratory test illustration

The TNG1049 Synthetic Blood Penetration Tester is designed to work alongside the TNG1044, offering a comprehensive testing solution for face masks. While the TNG1049 does not have detailed specifications listed, it is intended to provide additional testing capabilities that align with the ISO 22609 standard, ensuring thorough evaluation of mask performance.

What are the key parameters for synthetic blood penetration testing?

The TNG1044 provides a spraying time of 0.80 s, 0.66 s, and 0.57 s, which allows for precise control over the duration of synthetic blood exposure. This feature is essential for meeting the ISO 22609 standard, which requires specific time intervals to assess the effectiveness of face masks in preventing liquid penetration. The adjustable watching time of 10 seconds further supports the standard's requirement for accurate observation and measurement.

Instrument models referenced

  • TNG1044 Face Mask Synthetic Blood Penetration Tester (Air / Water / Vapour Permeability Testing). Published specifications include Blood spraying distance: (300 ± 10) mm; Nozzle inner diameter: 0.84 mm; Nozzle length: 12.7 mm.
  • TNG1049 Synthetic Blood Penetration Tester (Air / Water / Vapour Permeability Testing).

Editorial note. This application note summarises the published scope of the standard and our documented model data. Configuration requirements vary between standard editions, and instruments support a method only with the appropriate fixtures and accessories. Please confirm the required configuration against the applicable edition of the standard before ordering; conformity of a given test result also depends on the specimen and the procedure followed.

Instruments referenced

Test standards referenced

Need the instrument for this method?

Send the standard number and the material. We reply with the matching model, its full specification table and a quotation.

Tell us what you need to test.

Send the test method and the material. We will match the model, attach its specification table and reply with a written quotation - no prices published, no registration.