ASTM F1862: testing scope and instrument selection

Conclusion The TNG1044 model is designed to meet the requirements of ASTM F1862, ensuring accurate and reliable synthetic blood penetration testing for face masks.

Instrument Specifications and Their Relevance to ASTM F1862 The TNG1044, known as the Face Mask Synthetic Blood Penetration Tester, is specifically engineered to comply with ASTM F1862. This standard outlines the procedures for evaluating the resistance of face masks to synthetic blood penetration, which is critical for assessing their protective capabilities in medical and industrial settings. Two key specifications of the TNG1044 directly support the testing requirements of ASTM F1862. First, the blood spraying distance is set at (300 ± 10) mm. This specification ensures that the synthetic blood is delivered at a consistent and standardized distance from the mask, simulating real-world conditions where liquid exposure may occur at varying distances. By maintaining this distance, the test results are more representative of actual performance, enhancing the reliability of the evaluation. Second, the nozzle inner diameter is specified as 0.84 mm. This dimension is crucial for controlling the flow rate and pressure of the synthetic blood during the test. A consistent nozzle size ensures that the liquid is applied uniformly, which is essential for obtaining accurate and repeatable results. This specification aligns with the ASTM F1862 requirement for a controlled and reproducible application of synthetic blood, thereby supporting the validity of the test outcomes.
Additional Features Supporting ASTM F1862 Compliance The TNG1044 also includes a nozzle length of 12.7 mm, which contributes to the precision of the spraying process. This length ensures that the nozzle is positioned at the correct height relative to the mask, minimizing any potential interference with the test setup. Furthermore, the spraying speed options of 450 cm/s, 550 cm/s, and 635 cm/s allow for the simulation of different fluid dynamics scenarios, which is important for assessing the mask's performance under various conditions. The spraying time values of 0.80 s, 0.66 s, and 0.57 s provide flexibility in testing, enabling the evaluation of the mask's response to different exposure durations. The watching time of 10 seconds (adjustable) allows for the observation of any leakage or penetration of synthetic blood after the spraying event, which is a critical part of the ASTM F1862 test procedure. These specifications collectively ensure that the TNG1044 meets the rigorous standards set by ASTM F1862, providing laboratories with a reliable tool for assessing the protective efficacy of face masks.

Editorial note. This application note summarises the published scope of the standard and our documented model data. Configuration requirements vary between standard editions, and instruments support a method only with the appropriate fixtures and accessories. Please confirm the required configuration against the applicable edition of the standard before ordering; conformity of a given test result also depends on the specimen and the procedure followed.
Instruments referenced
Test standards referenced
Need the instrument for this method?
Send the standard number and the material. We reply with the matching model, its full specification table and a quotation.