TONNY INSTRUMENT TECHNOLOGY CO., LTD. Laboratory testing instruments since 2012

Preparing for ASTM D1907 testing: from method to instrument setup

Preparing for ASTM D1907 testing: from method to instrument setup - laboratory illustration

The Wrap Reel /B (TNG1090) is the recommended instrument for compliance with ASTM D1907, as it includes the required specifications to perform the test accurately.

Confirming the Method Code

Preparing for ASTM D1907 testing: from method to instrument setup - laboratory test illustration

Before procurement, it is essential to verify that the test method code aligns with the required standard. ASTM D1907 is the standard for determining the linear density of textile fibers, and the Wrap Reel /B (TNG1090) is specifically designed for this purpose. The instrument must be confirmed to support ASTM D1907, which is referenced in its specifications under ISO 2060 as "ASTM D1907 Step 1." This ensures that the device is compatible with the test procedure and can deliver reliable results.

Identifying the Required Measuring Range

The Wrap Reel /B (TNG1090) must be selected based on the required measuring range for the specific fiber type being tested. The instrument has a maximum load capacity of 45 kg, which is suitable for most textile fibers. Additionally, the length of the instrument is 900 mm, which is important for ensuring that the fiber can be wrapped and measured accurately without exceeding the physical limits of the device. These specifications ensure that the Wrap Reel /B (TNG1090) can handle a wide range of fiber types and thicknesses, making it a versatile choice for ASTM D1907 testing.

Checking the Published Specification Table

Preparing for ASTM D1907 testing: from method to instrument setup - laboratory test illustration

When reviewing the published specifications for the Wrap Reel /B (TNG1090), it is important to note the power requirements of 220/110 V at 50/60 Hz. This ensures that the instrument can be used in various laboratory environments with different electrical standards. The power specifications are critical for ensuring that the instrument operates reliably and consistently, which is essential for producing accurate and repeatable test results. By confirming these specifications, the procurement process can be streamlined, and the setup can be completed efficiently.

Requesting a Quotation

Once the method code, measuring range, and specifications have been verified, the next step is to request a quotation. The Wrap Reel /B (TNG1090) should be specified with the required parameters, including the maximum load capacity and length. This ensures that the quotation reflects the exact requirements for ASTM D1907 testing. By anchoring each step in the supplied instrument data, the procurement and setup process can be made more efficient and accurate.

Instrument models referenced

  • TNG1090 Wrap Reel /B (Fineness / Thickness / Length / Density Testing). Published specifications include 220/110 V 50/60 Hz; Length: 900 mm.

Editorial note. This application note summarises the published scope of the standard and our documented model data. Configuration requirements vary between standard editions, and instruments support a method only with the appropriate fixtures and accessories. Please confirm the required configuration against the applicable edition of the standard before ordering; conformity of a given test result also depends on the specimen and the procedure followed.

Instruments referenced

Test standards referenced

Need the instrument for this method?

Send the standard number and the material. We reply with the matching model, its full specification table and a quotation.

Tell us what you need to test.

Send the test method and the material. We will match the model, attach its specification table and reply with a written quotation - no prices published, no registration.

WhatsApp