Preparing for AATCC 195 testing: from method to instrument setup

The TNG1050 Moisture Management Tester is suitable for compliance with AATCC 195 due to its precise control of test conditions and accurate measurement of moisture transport properties.
Confirming the Method Code

Before procurement, it is essential to verify that the test method aligns with the required standard. AATCC 195 specifies the measurement of moisture management properties of textile materials, including wicking, drying, and moisture transfer. The TNG1050 is designed to meet these requirements by providing controlled environmental conditions and accurate data collection. Confirming the method code ensures that the selected instrument is capable of delivering reliable and repeatable results as defined by the standard.
Identifying the Required Measuring Range
The TNG1050 supports a wide range of testing parameters necessary for AATCC 195 compliance. The instrument's operation temperature and relative humidity range from 18°C to 40°C and 20% to 80% (non-condensing), respectively. This range accommodates the varying environmental conditions that may be required during testing. Additionally, the pump on time of 20 seconds ensures consistent application of test solution, which is critical for accurate moisture management measurements. These specifications are essential for simulating real-world conditions and ensuring the validity of test results.
Checking the Published Specification Table

The TNG1050's specifications, including its USB 1.1/2.0 interface and 110V~230V 50Hz/60Hz power supply, are crucial for integration into laboratory environments. The USB interface facilitates data transfer and software compatibility, while the power supply range ensures the instrument can operate in diverse electrical environments. The test solution's conductivity of 16 mS± 0.2 mS is a key parameter for ensuring the accuracy and consistency of moisture transport measurements. These specifications collectively support the precision and reliability needed for AATCC 195 testing.
Requesting a Quotation
To proceed with procurement, request a quotation that includes the TNG1050 model number, along with the specified parameters such as operation temperature and humidity range, pump on time, and test solution conductivity. Ensure that the quotation reflects the instrument's compliance with AATCC 195 requirements. This step ensures that the selected instrument meets the necessary standards and can be integrated seamlessly into the testing process.
Instrument models referenced
- TNG1050 Moisture Management Tester (Air / Water / Vapour Permeability Testing). Published specifications include Analysis Software Offered; Interface USB 1.1/2.0; Power Supply 110V~230V 50Hz/60Hz.
Editorial note. This application note summarises the published scope of the standard and our documented model data. Configuration requirements vary between standard editions, and instruments support a method only with the appropriate fixtures and accessories. Please confirm the required configuration against the applicable edition of the standard before ordering; conformity of a given test result also depends on the specimen and the procedure followed.
Instruments referenced
Test standards referenced
Need the instrument for this method?
Send the standard number and the material. We reply with the matching model, its full specification table and a quotation.