AATCC 16-2003 FAQ: instruments, ranges and method scope

The TNG1032 and TNG1036 Light Fastness Testers are designed to meet the AATCC 16-2003 standard for light fastness testing of textiles.
How do the TNG1032 and TNG1036 Light Fastness Testers meet the AATCC 16-2003 standard?

The TNG1032 and TNG1036 Light Fastness Testers are specifically engineered to comply with the AATCC 16-2003 standard, which outlines procedures for evaluating the light fastness of dyed textiles. These instruments replicate the effects of natural and artificial light exposure, ensuring accurate and repeatable results in accordance with the standard.
What irradiance settings are available on the TNG1032 and TNG1036?
The TNG1032 and TNG1036 offer an irradiance range of 0.80 to 1.50W/m² at 420nm, with the option to request additional wavelengths such as 340nm, 300–400nm, and 300–800nm. This range is critical for simulating various light exposure conditions as specified in AATCC 16-2003.
What is the irradiance accuracy of the TNG1032 and TNG1036?

The irradiance accuracy of the TNG1032 and TNG1036 is ±0.02W/m² at 420nm, ensuring precise control over light exposure during testing. This level of accuracy is essential for meeting the strict requirements of the AATCC 16-2003 standard, which demands consistent and reliable test results.
What temperature range does the TNG1032 and TNG1036 support?
The TNG1032 and TNG1036 operate within a temperature range of 25 to 50°C, with a resolution of 0.1°C. This range allows for precise temperature control, which is a key requirement in the AATCC 16-2003 standard to ensure that test conditions accurately reflect real-world environmental variations.
Instrument models referenced
- TNG1032 Light Fastness Tester (Colour Fastness Testing). Published specifications include Working modes To simulate and reinforce the impact of the nature of the measured object, providing light and dark, temperature and humidity, raining and other quantitative indicators.; Irradiance 0.80 ~ 1.50W/m2 @ 420nm (340nm, 300~400nm, 300~800nm is offered on request), Digital set, automatic closed-loop compensation; Irradiance accuracy ± 0.02W/m2 @ 420nm.
- TNG1036 Light Fastness Tester (Colour Fastness Testing). Published specifications include Working modes To simulate and reinforce the impact of the nature of the measured object, providing light and dark, temperature and humidity, raining and other quantitative indicators.; Irradiance 0.80 ~ 1.50W/m2 @ 420nm (340nm, 300~400nm, 300~800nm is offered on request), Digital set, automatic closed-loop compensation; Irradiance accuracy ± 0.02W/m2 @ 420nm.
Editorial note. This application note summarises the published scope of the standard and our documented model data. Configuration requirements vary between standard editions, and instruments support a method only with the appropriate fixtures and accessories. Please confirm the required configuration against the applicable edition of the standard before ordering; conformity of a given test result also depends on the specimen and the procedure followed.