The TNG1089 Digital Thickness Gauge and TNG1094 Fabric Thickness Tester /B are suitable for compliance with JIS L1096 Item 8.4 Method B due to their precise measurement capabilities and adjustable parameters.

What is the measuring accuracy of the TNG1089 Digital Thickness Gauge?

JIS L1096 Item 8.4 Method B FAQ: instruments, ranges and method scope - laboratory test illustration

The TNG1089 Digital Thickness Gauge has a measuring accuracy of 0.01mm, which aligns with the precision requirements of JIS L1096 Item 8.4 Method B. This level of accuracy ensures reliable and repeatable thickness measurements, essential for quality control in textile manufacturing.

What pressing foot areas are available on the TNG1094 Fabric Thickness Tester /B?

The TNG1094 Fabric Thickness Tester /B offers pressing foot areas of 100mm², 2000mm², 2500mm², and 10000mm². These options allow for testing different fabric types and thicknesses, ensuring that the measurement is representative of the material's true thickness as specified in JIS L1096.

What load weights are supported by the TNG1089 Digital Thickness Gauge?

JIS L1096 Item 8.4 Method B FAQ: instruments, ranges and method scope - laboratory test illustration

The TNG1089 supports load weights of 2cN x 2, 5cN x 1, 10cN × 2, 50cN × 2, 100cN x 1, 400cN x 1, and 1000cN × 2. This range of load weights enables the instrument to simulate various pressing conditions, ensuring that the test results are consistent with the standardized method outlined in JIS L1096.

How does the pressing speed of the TNG1094 Fabric Thickness Tester /B contribute to testing accuracy?

The TNG1094 Fabric Thickness Tester /B has a pressing speed of 1.72 mm/s, which is critical for achieving uniform pressure application during the test. This controlled speed helps prevent over-compression or under-compression of the fabric, ensuring that the thickness measurement is accurate and consistent with the JIS L1096 standard.

Instrument models referenced

  • TNG1089 Digital Thickness Gauge (Fineness / Thickness / Length / Density Testing).
  • TNG1094 Fabric Thickness Tester(Gauge) /B (Fineness / Thickness / Length / Density Testing).

Editorial note. This application note summarises the published scope of the standard and our documented model data. Configuration requirements vary between standard editions, and instruments support a method only with the appropriate fixtures and accessories. Please confirm the required configuration against the applicable edition of the standard before ordering; conformity of a given test result also depends on the specimen and the procedure followed.

Instruments referenced

Test standards referenced

Need the instrument for this method?

Send the standard number and the material. We reply with the matching model, its full specification table and a quotation.

Tell us what you need to test.

Send the test method and the material. We will match the model, attach its specification table and reply with a written quotation - no prices published, no registration.

WhatsApp